{"product_id":"la2-d22-time-delay-auxiliary-contact-module-no-nc-silver-point","title":"LA2-D22 Time Delay Auxiliary Contact Module NO+NC Silver Point","description":"\u003ch2\u003eLA2-D22 Air Delay Head – Time Delay Auxiliary Contact Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eLA2-D22 Time Delay Auxiliary Contact Module\u003c\/strong\u003e is a CE-certified, silver-point contactor add-on designed for reliable power-on delay control in industrial and commercial electrical systems. With an adjustable delay range of \u003cstrong\u003e0.1 to 30 seconds\u003c\/strong\u003e, this module mounts directly to compatible contactors, giving you precise timing control without extra wiring complexity.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e LA2-D22\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eContact Configuration:\u003c\/strong\u003e 1 NO (Normally Open) + 1 NC (Normally Closed)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower-On Delay Range:\u003c\/strong\u003e 0.1 – 30 seconds (adjustable)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eContact Type:\u003c\/strong\u003e Silver-point contacts for superior conductivity and durability\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e CE\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eMade in Mainland China\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhy Choose the LA2-D22?\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePlug-and-Play Mounting:\u003c\/strong\u003e Attaches directly to standard contactor bodies — no additional panel space required.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSilver-Point Contacts:\u003c\/strong\u003e Ensure low contact resistance, reliable switching, and extended service life even under frequent operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdjustable Delay (0.1–30s):\u003c\/strong\u003e Easily tuned to suit your application's exact timing needs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual Contact Output (NO + NC):\u003c\/strong\u003e Provides maximum wiring flexibility for a wide range of control circuit configurations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE Certified:\u003c\/strong\u003e Meets European conformity standards for electrical safety and performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor starter circuits requiring sequential power-on delays\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation and PLC control panels\u003c\/li\u003e\n  \u003cli\u003eHVAC and compressor control systems\u003c\/li\u003e\n  \u003cli\u003eConveyor and machine tool protection circuits\u003c\/li\u003e\n  \u003cli\u003eStar-delta (Y-Δ) starter transition timing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePackage Contents\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 × LA2-D22 Time Delay Auxiliary Contact Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eLooking for other electrical and DIY tools? Check out our \u003ca href=\"\/products\/air-compressor-pressure-gauge-0-10-0-12-0-25-bar-hydraulic-diy\"\u003eAir Compressor Pressure Gauge 0–25 Bar | DIY Tool\u003c\/a\u003e or our \u003ca href=\"\/products\/electromagnetic-induction-tester-coil-motherboard-fault-detector\"\u003eElectromagnetic Induction Tester – Coil \u0026amp; Circuit Fault Detector\u003c\/a\u003e for your workshop or control panel needs.\u003c\/p\u003e\n\n\u003cp\u003eLearn more: \u003ca href=\"https:\/\/www.osha.gov\/eye-face-protection\" target=\"_blank\" rel=\"noopener\"\u003eOSHA on eye and face protection\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: What contactors is the LA2-D22 time delay auxiliary contact module compatible with?\u003c\/h4\u003e\n\u003cp\u003eA: The LA2-D22 is designed to mount directly onto standard LC1\/LC2-series contactor bodies that accept LA2-series auxiliary contact blocks. Always verify the mechanical and electrical ratings of your specific contactor before installation to ensure compatibility.\u003c\/p\u003e\n\u003ch4\u003eQ: How do I adjust the power-on delay on the LA2-D22 module?\u003c\/h4\u003e\n\u003cp\u003eA: The LA2-D22 features a built-in adjustment dial that lets you set the power-on delay anywhere between 0.1 and 30 seconds. Simply rotate the dial to your desired delay time before energizing the circuit. No additional tools or components are required.\u003c\/p\u003e\n\u003ch4\u003eQ: What does NO + NC contact configuration mean on this module?\u003c\/h4\u003e\n\u003cp\u003eA: NO (Normally Open) means the contact is open when the coil is de-energized and closes after the set delay period. NC (Normally Closed) means the contact is closed when de-energized and opens after the delay. Having both gives you maximum flexibility for designing interlock, alarm, or sequencing circuits in your control panel.\u003c\/p\u003e\n\u003ch4\u003eQ: Is the LA2-D22 suitable for outdoor or harsh environments?\u003c\/h4\u003e\n\u003cp\u003eA: The LA2-D22 is intended for use within enclosed control panels or enclosures. It is not rated for direct outdoor exposure. For harsh or wet environments, ensure it is installed inside an appropriately rated (IP65 or higher) enclosure for protection.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What contactors is the LA2-D22 time delay auxiliary contact module compatible with?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The LA2-D22 is designed to mount directly onto standard LC1\/LC2-series contactor bodies that accept LA2-series auxiliary contact blocks. Always verify the mechanical and electrical ratings of your specific contactor before installation to ensure compatibility.\"}}, {\"@type\": \"Question\", \"name\": \"How do I adjust the power-on delay on the LA2-D22 module?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The LA2-D22 features a built-in adjustment dial that lets you set the power-on delay anywhere between 0.1 and 30 seconds. Simply rotate the dial to your desired delay time before energizing the circuit. No additional tools or components are required.\"}}, {\"@type\": \"Question\", \"name\": \"What does NO + NC contact configuration mean on this module?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"NO (Normally Open) means the contact is open when the coil is de-energized and closes after the set delay period. NC (Normally Closed) means the contact is closed when de-energized and opens after the delay. Having both gives you maximum flexibility for designing interlock, alarm, or sequencing circuits in your control panel.\"}}, {\"@type\": \"Question\", \"name\": \"Is the LA2-D22 suitable for outdoor or harsh environments?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The LA2-D22 is intended for use within enclosed control panels or enclosures. It is not rated for direct outdoor exposure. For harsh or wet environments, ensure it is installed inside an appropriately rated (IP65 or higher) enclosure for protection.\"}}]}\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"BreadcrumbList\", \"itemListElement\": [{\"@type\": \"ListItem\", \"position\": 1, \"name\": \"Home\", \"item\": \"https:\/\/n8ande-60.myshopify.com\/\"}, {\"@type\": \"ListItem\", \"position\": 2, \"name\": \"Home page\", \"item\": \"https:\/\/n8ande-60.myshopify.com\/collections\/frontpage\"}, {\"@type\": \"ListItem\", \"position\": 3, \"name\": \"LA2-D22 Time Delay Auxiliary Contact Module NO+NC Silver Point\", \"item\": \"https:\/\/n8ande-60.myshopify.com\/products\/la2-d22-time-delay-auxiliary-contact-module-no-nc-silver-point\"}]}\u003c\/script\u003e","brand":"Axl","offers":[{"title":"LA2-D22","offer_id":43699461455933,"sku":"14:350850#LA2-D22","price":41.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/3439\/0333\/files\/H35f9083d0b80490d848c3bf7016ad495R.webp?v=1790183755","url":"https:\/\/qtiply.com\/products\/la2-d22-time-delay-auxiliary-contact-module-no-nc-silver-point","provider":"QTP","version":"1.0","type":"link"}